13
8 Special Functions
Capture Function: The Capture function is used to obtain
a single reading and keep it displayed. This may be useful
when the unit may not be visible and grade information
needs to be obtained.
When in the laser beam and power on, momentarily press the
Power/Capture switch. The current elevation reading will be saved.
A ashing display will conrm the reading has been captured.
Press any switch to return to normal operation.
When out of the laser beam and power on, momentarily press
the Power/Capture switch. A short intermittent beep and 'WAIT'
displayed on the LCD conrm the Capture mode. (The beeper will
turn on to Low if turned off.) Place the receiver in the beam. The
beeper will chirp rapidly after approximately 5 seconds conrming
beam capture. A ashing display will also conrm the reading has
been captured. Press any switch to return to normal operation.
Calibration Mode: Pressing the Power and
Accuracy switches together when the unit is off
enables entry into a laser calibration accuracy mode.
This mode is not marked on the unit.
This accuracy is designed to be used when calibrating a laser.
It is not recommended for eld use. Refer to §11, Specications,
for calibration mode values.
Calibration mode will be conrmed on the LCD by the accuracy
indicators without the on-grade bar.
Press any key or cycle power to exit the calibration mode and
return to the previously stored accuracy setting.